INVERTER & PCS
From rooftop solar to a battery microgrid, select the operating mode, electrical interfaces and control architecture together.
Explore system architectureSTART WITH THE OPERATING ROLE
Operating mode and coupling method are separate decisions. We work through both.
01
Converts solar DC to grid-synchronised AC. A conventional grid-following unit needs a live grid and does not by itself provide outage backup.
02
Creates an independent AC supply using a suitable battery and charging arrangement. Generator charging and parallel operation depend on the selected model.
03
Coordinates solar, a supported battery and grid / backup circuits. AC coupling, generator input and transfer capability are checked model by model.
BIDIRECTIONAL BATTERY POWER CONVERSION
Charging and discharging between the battery and AC system. Grid-forming, grid-following and transfer requirements are part of selection.
Multiple conversion units, often assigned to individual battery racks or clusters. Review independent control, fault isolation and parallel coordination.
Battery strings feed a shared conversion block. Review DC combining, protection, current sharing and the effect of a converter outage.
EXPLORE THE ENERGY PATH
Change the operating mode, PV coupling and generator option to see how the architecture changes.
Operating mode
PV connection
Battery energy passes through the PCS to the AC bus. The EMS schedules operation within the PCS, battery and grid-connection limits.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV has its own inverter. Solar and battery power meet on the AC bus, a useful arrangement when retaining a compatible existing solar plant.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV connects through an MPPT / DC–DC stage to the battery-side DC bus. The bidirectional conversion stage exchanges power with the AC system.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV has its own inverter. Solar and battery power meet on the AC bus, a useful arrangement when retaining a compatible existing solar plant.
The PCS or inverter must establish voltage and frequency. PV output needs compatible curtailment and coordination with battery SOC and load changes.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV has its own inverter. Solar and battery power meet on the AC bus, a useful arrangement when retaining a compatible existing solar plant.
The PCS or inverter must establish voltage and frequency. PV output needs compatible curtailment and coordination with battery SOC and load changes.
Generator start / stop, charging limits, minimum loading and reverse-power protection are coordinated. A multi-function inverter port may not support generator and AC-coupled PV at the same time.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV connects through an MPPT / DC–DC stage to the battery-side DC bus. The bidirectional conversion stage exchanges power with the AC system.
The PCS or inverter must establish voltage and frequency. PV output needs compatible curtailment and coordination with battery SOC and load changes.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV connects through an MPPT / DC–DC stage to the battery-side DC bus. The bidirectional conversion stage exchanges power with the AC system.
The PCS or inverter must establish voltage and frequency. PV output needs compatible curtailment and coordination with battery SOC and load changes.
Generator start / stop, charging limits, minimum loading and reverse-power protection are coordinated. A multi-function inverter port may not support generator and AC-coupled PV at the same time.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV has its own inverter. Solar and battery power meet on the AC bus, a useful arrangement when retaining a compatible existing solar plant.
The transfer / isolation arrangement separates the backup circuit from the grid during an outage. Transfer time and critical-load capacity are selected for the application.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV has its own inverter. Solar and battery power meet on the AC bus, a useful arrangement when retaining a compatible existing solar plant.
The transfer / isolation arrangement separates the backup circuit from the grid during an outage. Transfer time and critical-load capacity are selected for the application.
Generator start / stop, charging limits, minimum loading and reverse-power protection are coordinated. A multi-function inverter port may not support generator and AC-coupled PV at the same time.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV connects through an MPPT / DC–DC stage to the battery-side DC bus. The bidirectional conversion stage exchanges power with the AC system.
The transfer / isolation arrangement separates the backup circuit from the grid during an outage. Transfer time and critical-load capacity are selected for the application.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
PV connects through an MPPT / DC–DC stage to the battery-side DC bus. The bidirectional conversion stage exchanges power with the AC system.
The transfer / isolation arrangement separates the backup circuit from the grid during an outage. Transfer time and critical-load capacity are selected for the application.
Generator start / stop, charging limits, minimum loading and reverse-power protection are coordinated. A multi-function inverter port may not support generator and AC-coupled PV at the same time.
EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.
Conceptual architecture. Final protection, transfer, communication and grid requirements are confirmed for the selected equipment and site.
FROM A SITE BRIEF TO A COORDINATED CONFIGURATION
A clear equipment list, compatible interfaces and an agreed control sequence reduce decisions left to the installation stage.
Continuous kW / kVA, motor starting loads, phase imbalance, critical circuits, autonomy and acceptable transfer time.
New or existing array, string voltage and current, MPPT range, AC-coupled inverter control and export limits.
Full battery voltage window, charge / discharge current, C-rate, usable energy, BMS protocol and model compatibility.
Generator rating, start signal, minimum loading, reverse-power protection, inverter port allocation and supported parallel arrangements.
AC voltage, phases, frequency, connection requirements, metering, EMS dispatch, tariffs and requested operating priorities.
Temperature, altitude, enclosure rating, ventilation, access, spare capacity, expansion stages and commissioning scope.