INVERTER & PCS

The right conversion.
For the whole system.

From rooftop solar to a battery microgrid, select the operating mode, electrical interfaces and control architecture together.

Explore system architecture

START WITH THE OPERATING ROLE

Inverter or PCS?
Then, which architecture?

Operating mode and coupling method are separate decisions. We work through both.

01

On-grid inverter

PV → AC → Grid / loads

Converts solar DC to grid-synchronised AC. A conventional grid-following unit needs a live grid and does not by itself provide outage backup.

02

Off-grid inverter

PV / battery → Stand-alone loads

Creates an independent AC supply using a suitable battery and charging arrangement. Generator charging and parallel operation depend on the selected model.

03

Hybrid inverter

PV + battery + grid / backup

Coordinates solar, a supported battery and grid / backup circuits. AC coupling, generator input and transfer capability are checked model by model.

BIDIRECTIONAL BATTERY POWER CONVERSION

PCS: two architectures.

Charging and discharging between the battery and AC system. Grid-forming, grid-following and transfer requirements are part of selection.

String / distributed PCS

Rack 1PCS 1Rack 2PCS 2Rack 3PCS 3AC bus

Multiple conversion units, often assigned to individual battery racks or clusters. Review independent control, fault isolation and parallel coordination.

Centralized PCS

Rack 1Rack 2Rack 3Central PCSAC busDC bus

Battery strings feed a shared conversion block. Review DC combining, protection, current sharing and the effect of a converter outage.

EXPLORE THE ENERGY PATH

Choose a setup. See the connections.

Change the operating mode, PV coupling and generator option to see how the architecture changes.

Operating mode

PV connection

Grid-connected storage · DC coupled PV

PV connects through an MPPT / DC–DC stage to the battery-side DC bus. The bidirectional conversion stage exchanges power with the AC system.

AC BUSGridAC connectionSite loadsAC loadsPV arrayMPPT / DC-DCSolar DC inputHybrid inverterDC ⇄ ACBatteryBMS protectedDC LINKEMS / BMSCoordination & limits
Configuration checks

EMS coordinates operation; BMS protects and reports battery limits. Confirm CAN / RS485 / LAN protocols, firmware and tested model compatibility.

AC powerDC powerControl / communication

Conceptual architecture. Final protection, transfer, communication and grid requirements are confirmed for the selected equipment and site.

FROM A SITE BRIEF TO A COORDINATED CONFIGURATION

We work through
the interfaces for you.

A clear equipment list, compatible interfaces and an agreed control sequence reduce decisions left to the installation stage.

Load & backup

Continuous kW / kVA, motor starting loads, phase imbalance, critical circuits, autonomy and acceptable transfer time.

PV & coupling

New or existing array, string voltage and current, MPPT range, AC-coupled inverter control and export limits.

Battery interface

Full battery voltage window, charge / discharge current, C-rate, usable energy, BMS protocol and model compatibility.

Generator & parallel operation

Generator rating, start signal, minimum loading, reverse-power protection, inverter port allocation and supported parallel arrangements.

Grid & controls

AC voltage, phases, frequency, connection requirements, metering, EMS dispatch, tariffs and requested operating priorities.

Site & future expansion

Temperature, altitude, enclosure rating, ventilation, access, spare capacity, expansion stages and commissioning scope.

01 · Define the operating requirement02 · Coordinate equipment & interfaces03 · Confirm the configuration & commissioning sequence

INVERTER PARTNERS

Choice, coordinated.

Deye
Solis
Megarevo
SRNE
SAJ
Growatt
GoodWe
Huawei
Sungrow
ATESS

YOUR PROJECT. OUR NEXT CONVERSATION.

Understand the connections.
Let us configure the system.

Explore the technical options here, then bring your application to System Design for a coordinated equipment proposal.